uPvC Electrical Conduit & Duct System

Designed for Pressure. Built for Endurance.

uPvC Electrical Conduit & Duct System


Bending of Oman Therm uPvC Electrical Conduit Pipes

To bend circular conduit, insert the appropriate spring. The spring has an “eye” formed on one end, to which a cord should be attached in order to withdraw the spring. The bend is then made by hand or across the knee. Twice the angle required should be bent and the tube then allowed easing back to the desired position. Do not attempt to force the bend back with the spring inserted, as this action will damage the spring. When withdrawing the spring it is suggested that it be twisted in an anti-clockwise direction thus reducing the diameter of the spring and providing easy withdrawal. It is important to use the correct size spring. In cold weather it may be necessary to warm the tube slightly at the point where the bend is to be made. Always saddle the tubing as quickly as possible after bending.


Nominal Size (mm) min Wall thickness (mm) Inside Diameter ID mm
Light medium Heavy Light medium Heavy
16 1.15 1.5 1.9 13.7 13.0 12.2
19 1.2 1.4 2.0 16.6 16.2 15.0
20 1.3 1.5 2.1 17.4 17.0 15.8
25 1.4 1.8 2.2 22.2 21.4 20.6
32 1.9 2.1 2.7 28.2 27.8 26.6
38 1.8 2.45 2.75 34.4 33.1 32.5
50 2.45 2.85 3.4 45.1 44.3 43.2
  • Color: Black & White
  • Solvent Cement can be used for jointing
  • Standard Length 2.9m & 3.0m
  • Note:
  • Plain pipes and socketing pipes are available as per customer requirements.

pvc-u Telephone duct

din 8061/8062 series 3 Omantal/Ooredoo/OBB


Standard Length: 6 Metres

Colour: Socket Grey/ Black

Type: Solvent Weld


Nominal Size mm Outside Diameter mm Wall thickness mm
50 50.0 1.8
110 110.0 3.2

pvc-u conduits for cables

Bs En 61386-24


Standard Length: 3 Metres

Colour: Socket Black

Type: Solvent Weld


Pipe Size mm Outside Diameter Min. inside diameter mm Wall Thickness N 450 Wall Thickness N 750
Min Max mm Min Max Min Max
50 50 51 37 - - - -
75 75 76.4 56 2.6 3.1 3.0 3.5
90 90 91.7 67 2.9 3.2 - -
110 110 112 82 3.2 3.8 4.5 5.0
160 160 162.9 122 5.0 6.0 - -

pvc-u Non Pressure Pipe

to Bs: 3506 (class B, C, D & E) 1969


Standard Length: 6 Metres

Colour: Socket Dark Grey

Type: Solvent Weld


Nominal Size Outside Diameter Wall Thickness Wall Thickness Wall Thickness Wall Thickness
Class D Class C Class D Class E
Inch Min/mm Max/mm Min/mm Max/mm Min/mm Max/mm Min/mm Max/mm Min/mm Max/mm
2 60.2 60.5 - - 2.5 3.0 3.1 3.7 3.9 4.5
3 88.7 89.1 2.9 3.4 3.5 4.1 4.6 5.3 5.7 6.6
4 114.1 114.5 3.4 4.0 4.5 5.2 6.0 6.9 7.3 8.4
6 168.0 168.5 4.5 5.2 6.6 7.6 8.8 10.2 10.8 12.5
8 218.8 219.4 5.3 6.1 7.8 9.0 10.3 11.9 12.6 14.5
10 272.6 273.4 6.6 7.6 9.7 11.2 12.8 14.8 15.7 18.1
12 323.4 324.3 7.8 9.0 11.5 13.3 15.2 17.5 18.7 21.6

pvc-u Conduits

Omani standard 109/1986


Standard Length: 3 Metres

Colour:Light Gray/ Dark Black


Nominal size Outside Diameter mm Minimum Inside Dia.
mm Dimension Tolerance mm
16 16 -0.2 13.0
20 20 -0.30 16.9
25 25 -0.3 21.4
32 32 -0.40 27.8

pvc-u Conduits FOR Cables

Bs En 61386-24


Standard Length: 6 Metres

Colour:Light Gray/ Dark Black

Type: Solvent Weld


Pipe Size mm Outside Diameter mm Min. inside diameter Wall Thickness N 450 Wall Thickness N 750
Min Max mm Min Max Min Max
50 50 51 37 - - 3.0 3.5
75 75 76.4 56 2.6 3.1 - -
90 90 91.7 67 2.9 3.2 - -
110 110 112 82 3.2 3.8 4.5 5.0
160 160 162.9 122 5.0 6.0 - -